SAR Antenna Testing.

This MGSE is specifically designed to perform the Near Filed measuring of the SAR antenna panels, in Anechoic Chamber, during the Thermal Test. A dedicated Thermal Chamber is used in Anechoic Chamber.

The MGSE is radio frequency transparent

The Mechanical stability is studied to compensate the thermal behaviour of the materials.

The machine showed below, delivered in Argentina for SaoCom mission, has:

  • 6000 mm height,
  • 5 Degrees of Freedom,
  • 0,005° of accuracy,
  • Working Temperature -70 to +70 °C,
  • Fully integrated with Thermal Chamber by ATT (Angelantoni Company),
MGSE and Thermal Chamber

MGSE and Thermal Chamber

MGSE during tilting

Elital MGSE with Satellite SAR Antenna Panel mounted on-board

Elital MGSE with Satellite SAR Antenna Panel mounted on-board

MGSE @ 90° - 6m height with 0,1mm accuracy

MGSE @ 90° – 6m height with 0,1mm accuracy